Canopy T1/E1 Multiplexer

September 2004

 

T1/E1 Multiplexer FPGA Version 3.4

3.2T1/E1 ALARMS

Each T1/E1 channel has alarms for line code violation (BPV), receive loss of signal (LOS), and alarm indication signal (AIS) detection.

Follow these steps to display the alarms using the CLI.

Procedure 23: Displaying the alarms using the CLI

Action

Log in

View T1/E1 Alarms

Log off

Steps

Press Enter.

At the username prompt, enter admin.

At the password prompt, enter password.

Enter get alarms.

The system responds displays alarms for all 4 T1/E1 ports, as in the following example:

Line1:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

Line2:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

Line3:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

Line4:

Line code violation: No

Receive Loss of Signal: No

Alarm Indication Signal Detect: No

FPGA: 00

Enter lo.

RESULT: The system responds goodbye.

end of procedure

Issue 3

Page 54 of 73

Page 54
Image 54