Canopy T1/E1 Multiplexer

September 2004

 

T1/E1 Multiplexer FPGA Version 3.4

Procedure 12: Configuring the E1 ports using the CLI

Follow this procedure to configure the E1 ports from the CLI manager.

Action

Steps

 

 

Log in

Press Enter.

 

At the username prompt, enter admin.

 

At the password prompt, enter password.

 

 

Set E1 line length

NOTE: If the incorrect line length is selected, the result could be decreased

 

E1 quality or echo on voice lines. The default length is 133 ft.

 

Enter set line [1/2/3/4] length [133, 266, 399, 533]

 

where

 

[1/2/3/4] represents E1 ports 1 through 4.

 

[133, 266, 399, 533, 655] represents line length in feet.

 

RESULT: The system responds

 

Line [1/2/3/4] length [0-133 / 0.6 dB; 133-266 / 1.2

 

dB; 266-399 / 1.8 dB; 399-533 / 2.4 dB; 533-655 / 3.0

 

dB]

 

 

Set E1 line code

NOTE: If the line code does not match the incoming E1 settings, then

 

Bipolar Violations (BPVs) will occur. The default code is HDB3.

 

Enter set line [1/2/3/4] code [HDB3/AMI]

 

where

 

[1/2/3/4] represents E1 ports 1 through 4.

 

[HDB3/AMI] represents the line coding scheme.

 

RESULT: The system responds

 

Line [1/2/3/4] code [HDB3/AMI]

 

 

Issue 3