Desa VS42H(1), S42R Fireplace Installation, WARNING Hearth extension, Continued, Hearth Extension

Models: S42RH S42R VS42(1) VS42H(1) S42H S42

1 20
Download 20 pages 1.5 Kb
Page 5
Image 5
Continued

FIREPLACE INSTALLATION

Continued

Note: For outdoor installations, the fireplace en- closure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the fireplace within the fireplace enclosure.

HEARTH EXTENSION

A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fire- place. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply:

0.25x 1.0" = 0.30" thickness required

Thermal conductivity "K" of materials can be obtained from the manufacturer or supplier of the noncombustible material. If the hearth extension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a non- combustible material (see Figure 3).

HEARTH EXTENSION WARNING: Hearth extension

is to be installed only as shown

in Figure 3.

Seal Gap

Fireplace Front

MANTELS

 

 

 

 

 

A mantel may be installed if desired (see Figure

4). Woodwork such as wood trims, mantels or

any other combustible material projecting from

the front face must not be placed within 12" of

the fireplace opening. Combustible materials

above 12"

and

projecting more than 1

1

/2" from

 

the fireplace must not be placed less than 15"

from the top opening of the fireplace (NFPA STD

211, Sec. 7-3.3.3).

 

 

 

Mantels or any other combustible material also

may come up to the side edge of the black metal

face of the fireplace just as long as the projection

from the front face fall within the limit shown in

Figure 4.

 

 

 

 

 

 

 

 

 

 

Combustible

 

12

1

/4" Ref.

Material

 

 

 

 

 

 

Safe

6"

 

 

 

Zone for

Ref.

33°

 

Projection of

 

 

Combustible

 

 

 

 

 

3" Nom.

Materials

 

 

 

 

15" Min.

1

 

 

 

 

1

/2" Max.

 

 

 

12"

Min.

Upper

 

Section of

 

 

 

 

 

 

 

 

Fireplace

 

Fireplace

 

 

 

 

Opening

 

 

 

Top View of Fireplace

 

 

 

 

 

 

 

FIREBOX

 

 

8.0"

 

 

 

 

 

 

Ember Protector WARNING: Hearth extension

Fireplace Front

Raised Hearth

Ember Protector is to be installed only as shown

Fireplace Front

Elevated

Hearth

Extension

Seal Gap MANTELS

 

2" Max.

SAFE ZONE

3.0"

33°

 

Min. to

 

Perpendicular

Combustible

Side Wall

Material Must

12"

Not Overlap

 

 

Front Face

Figure 4 - Mantel Clearances to

Combustible Material

Ember ProtectorFigure 3 - Hearth Extension

Figure 3 - Hearth Extension

111099-01C

www.desatech.com

5

Page 5
Image 5
Desa VS42H(1) Fireplace Installation, WARNING Hearth extension, is to be installed only as shown in Figure, Continued