Desa VS42H(1) Venting Installation, Optional Gas Line Installation, Continued, Gas Line Knockout

Models: S42RH S42R VS42(1) VS42H(1) S42H S42

1 20
Download 20 pages 1.5 Kb
Page 11
Image 11
Figure 18 - Typical Residential Installations

VENTING INSTALLATION

Continued

EFFECTIVE HEIGHT OF

EFFECTIVE HEIGHT OF

TERMINATION CAP

TERMINATION CAP

14.5 FT.

14.5 FT.

MINIMUM

MINIMUM

HEIGHT

HEIGHT

UP TO 6FT.

MAXIMUM

EFFECTIVE HEIGHT OF

TERMINATION CAP

MAXIMUM HEIGHT 50 FT. (ANY SYSTEM)

UP TO 6 FT.

MAXIMUM

OPTIONAL GAS LINEFigure 19 - Gas Line Knockout 30E-8DM

EFFECTIVE HEIGHT OF

TERMINATION CAP

MINIMUM HEIGHT OF 22 FT. (WITH TWO ELBOW SETS) MAXIMUM HEIGHT OF 50 FT.

Manual background 30E-8DM

Figure 18 - Typical Residential Installations

OPTIONAL GAS LINE

INSTALLATION

Gas line hook up should be done by your supplier or a qualified service person.

Note: Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.

1.Remove knockout indentation on refractory or firebrick wall located above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 19).

2.Remove gas line cover plate located on either side of fireplace and pull out insulation from gas line conduit sleeve. Save insulation for reuse. Replace screws.

3.Run a 1/2" black iron gas line into the fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 20, page 12). Note: Secure incoming gas line to wood framing to provide rigidity for threaded end.

4.Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory ce- ment or commercial furnace cement, Install the gas appliance or cap-off gas line if desired.

Outside of

Side

Firebrick

Fireplace

Finished

 

Gas Line

Side

 

Conduit

 

Insulation

1/2" Dowel

 

Gas

 

Conduit

Refractory

Cover

Knockout

 

 

Plug

Figure 19 - Gas Line Knockout

111099-01C

www.desatech.com

11

Page 11
Image 11
Desa VS42H(1), S42R Venting Installation, Optional Gas Line Installation, Continued, Typical Residential Installations