VENTING INSTALLATION

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)

The installation of an outside air kit should be per- formed during the rough framing of the fireplace due to the nature of it's location. Outside combus- tion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).

OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F) CAUTION: Combustion air inlet ducts shall not terminate in attic space.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

42"

Fireplace

44"

12-8DM

Pipe Section

10 5/8"

12-8HT

 

 

18-8DM

Pipe Section

16 5/8"

18-8HT

 

 

24-8DM

Pipe Section

23 5/8"

24-8HT

 

 

36-8DM

Pipe Section

34 5/8"

36-8HT

 

 

48-8DM

Pipe Section

46 5/8"

48-8HT

 

 

RT-8DM

Round Termination

6 7/8"*

RTL-8DM

Round Termination

7 3/4"*

RTT-8DM

Round Termination

6 7/8" to

with Slip Section

23 1/8"*

 

RTTL-8DM

Round Termination

8 1/2" to

with Slip Section

21 1/2"*

 

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top

12"*

 

with Mesh

 

ETL-8DM

Square Chase-Top

7" to 15"*

 

with Slip Section

 

 

Square Chase-Top

12" to

ETLO-8DM

with Mesh & Slip

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

Air Inlet Eyebrow

Vent Hood Required for Wall Installation

Section

25 1/2"*

 

*The lineal gain for the terminations is mea- sured to the flue gas outlet height.

12" Galvanized

Outer Pipe

Figure 5 - Outside Air Kit

CHIMNEY PIPE

The DESA chimney system consists of 12", 18", 24", 36" and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 6). Lineal gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".

Figure 5 - Outside Air Kit WARNING: The opening in the collar around the chimney at the top of the fireplace must not be obstructed.Neveruseblowninsula- tion to fill the chimney enclosure.

12

3

/8"

 

 

 

 

Hemmed

 

 

 

 

 

End

Stainless

 

Inner Pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6 - Lineal Gain

 

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a

galvanized outer pipe, a stainless steel inner flue

pipe and a wire spacer. The pipe sections must be as-

sembled independently as the chimney is installed.

When connecting chimney directly to the fireplace,

the inner flue pipe section must be installed first

with the lanced side up. The outer pipe section can

then be installed over the flue pipe section with the

hemmed end up. Press down on each pipe section

until the lances securely engage the hem on the fire-

place starter. The wire will assure the proper spacing

between the inner and outer pipe sections.

6

www.desatech.com

111099-01C