PRE-INSTALLATION PREPARATION
WARNING: A qualified ser- vice person must install fireplace. Follow all local codes.
CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating fireplace where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient lo- cation for your Vanguard
On Wall with Vertical Corner Installation Termination Through with Vertical
CeilingTermination Through Ceiling
Figure 2 - Common Freestanding Fireplace Locations
Ceiling
42"
36" | 4" |
from |
|
Front |
|
| Back |
| Wall |
| Floor |
Must Maintain a Minimum
of 1" Clearance to Combustibles
29"
When deciding the location of your fire- place, follow these rules:
1.Do not connect this fireplace to a chim- ney flue serving a separate
2.Due to high temperatures, do not lo- cate this fireplace in high traffic areas or near furniture or draperies.
3.Proper clearances must be maintained, see Figure 3 and Figure 4 on page 5.
4.This stove is a freestanding unit de- signed to set directly on the floor. If your fireplace is to be installed directly on carpeting, vinyl tile, or any combus- tible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 5, page 5.
4"
6"
Front
Figure 3 - Clearances for Standard Installation
4 | 105500 |