CLEANING AND MAINTENANCE

TROUBLE-

SHOOTING

Note: All troubleshooting items are listed in order of operation.

WARNING

WARNING ICON

G 001

Turn off heater and let cool before cleaning.

CAUTION

WARNING ICON

G 001

You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

• Replace log(s) if broken or chipped (dime-sized or larger).

WARNING

WARNING ICON

G 001

Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION

WARNING ICON

G 001

Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

When ignitor button

1.

Ignitor electrode not con-

1.

Reconnect ignitor cable

is pressed, there is no

 

nected to ignitor cable

 

 

spark at ODS/pilot

2.

Ignitor cable pinched or

2.

Free ignitor cable if

 

 

wet

 

pinched by any metal or

 

 

 

 

tubing. Keep ignitor

 

 

 

 

cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding

 

 

 

 

piezo ignitor to base

 

 

 

 

panel of log set. Nut is

 

 

 

 

located behind base

 

 

 

 

panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode posi-

6.

Replace ignitor

 

 

tioned wrong

 

 

 

7.

Ignitor electrode broken

7.

Replace ignitor

Continued

104024

21

Page 21
Image 21
Desa SVYD18N installation manual Cleaning and Maintenance Trouble Shooting, ODS/PILOT and Burner, Logs