OPERATING FIREPLACE

Optional Hand-Held Remote Operation (Cont.) Operating Optional GWMT1 Wall Mounted Thermostat

OPERATING FIREPLACE

Continued

ON/OFF SERIES

(Model HRC200 and HRC201)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 52).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Indicator

 

Light

Control

 

 

Button

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the re- ceiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centigrade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand- held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

Figure 52 - On/Off Hand-Held Remote Control Unit (HRC100/HRC101)

THERMOSTAT SERIES

(Model GHRCTB and CGHRCTB)

The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 53). To selectFahrenheit/Centigrademodedisplay,carefullypressthe˚C/˚F mode button with the end of a paper clip or similar blunt object.

Indicator Safety Features Light

Locks System to Prevent Accidental Ignition

 

AUTO

ROOM

SET

TEMP

TEMP

LOCK

TEMP

POWER

 

Digital Display

Shows Temperature

and Settings

Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace.

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Turns

MANU

ºC/ºF

AUTO

Burners

 

Selects

 

 

On or Off

 

 

 

 

AUTO Mode

 

 

 

Increases or

 

 

°C/°F Mode

 

 

Button

Decreases Room

 

 

 

 

 

Temperature in

 

 

 

AUTO Mode

 

 

 

Figure 53 - Thermostat Hand-Held Remote Control Unit (HRC200/HRC201)