FIREPLACE INSTALLATION
Checking Gas Connections (Cont.) Installing Optional Wall Mount Switch - GWMS2 Installing Optional Wireless
21
FIREPLACE INSTALLATION
Continued
Pressure Testing Fireplace Gas Connections
1.Open equipment shutoff valve (see Figure 33, page 20).
2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.
3.Make sure control knob of fireplace is in the OFF position.
4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas, page 20). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
5.Light fireplace (see Operating Fireplace, pages 25 through 27). Check all other internal joints for leaks.
6.Turn off fireplace (see To Turn Off Gas to Appliance, page 25).
INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2
1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 36. If wires are not connected as shown the switch will not work.
2.Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch.
3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.
4.Install the wall switch and cover in the wall.
To Wall Switch
Accessory
Figure 36 - Connecting Wall Swith to Control Valve
INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES
4.Attach the terminal wires to the battery.
5.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).
7.Replace the switch bracket.
Receiver
To Optional
Remote Accessory
or Wall Switch
Terminal
Battery Wires
Clip
Battery
Figure 37 - Attaching Alkaline | Figure 38 - Control Valve |
Battery to Receiver | Terminals |
Installing
1.Remove battery cover on back of remote control unit.
2.Attach terminal wires to a
3.Replace battery cover onto remote control unit.
| Battery Cover | Remote |
Terminal |
| |
| Control Unit | |
Wires |
|
|
Battery
Housing
Figure 39 - Installing Alkaline Battery in Hand-Held Remote Control Unit ([C]GHRCB)
| Terminal |
Wires | |
| |
Battery |
|
NOTICE: Use only alkaline batteries (not included).
Installing Remote Receiver
1. | Open bottom louver and locate the switch bracket on the left. |
2. | Unscrew the switch bracket. Lean bracket forward so you are |
Battery Cover
Remote
Control
Unit
able to access the back of the remote receiver. |
Figure 40 - Installing Battery in Hand-Held Remote Control Unit ([C]GHRCTB Series)
3.Locate the battery clip mounted on the back of the receiver. Slide a
For more
visit www.
.com