Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER Installation, Continued, Gas Connection

Models: UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

1 24
Download 24 pages 28.18 Kb
Page 11
Image 11
Figure 14 - Gas Connection

OWNER’S MANUAL

INSTALLATION

Continued

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

13.Pointing the vent down protects it from freezing rain or sleet.

External

Regulator

Propane

Supply Tank

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

Vent Pointing

Down

Figure 13 - External Regulator With Vent Pointing Down

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.

A.G.A. Design-Certified

Manual Shutoff Valve

With 1/8" NPT Tap*

From External

Regulator (11"

W.C.** to 14"

W.C. Pressure)

Tee Joint

 

Pipe

3" Minimum

Nipple

 

Cap

 

Sediment

Trap

Approved Flexible Gas Hose (if allowed by local codes)

Gas

Regulator

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Figure 14 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page19.

**Minimum inlet pressure for purpose of input adjustment.

Continued

104256

11

Page 11
Image 11
Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER installation manual Installation, Continued, Gas Connection