Mantel Clearances

VANGUARD FLAME-MAX™

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

Mantel Clearances

In addition to meeting non-combustible material clearances, you must also meet reaquired clearances between fireplace open- ing and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

Determing Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clear- ance When using a Hood

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

12"

 

 

 

 

 

 

8"

 

 

 

 

Mantel Shelf

20"

 

241/2"

271/2"

 

14"

 

163/4"

181/2"

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

30" Manual background 24”/30”/36” Models

20" Manual background 18" Model

Top of Fireplace

Opening

If your installation does not meet the above minimum clearances, you must:

operate the logs only with the flue damper open, OR

raise the mantel to an acceptable height,

OR

remove the mantel.

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

 

12"

 

 

 

10"

 

 

 

8"

 

 

 

6"

 

 

 

2 1/2"

 

 

Minimum Non-

 

 

 

Combustible

 

 

 

Material

8"

12"

15"

 

 

Min.

 

 

Hood

Distances to

(GA6050, GA6052)

Underside of

 

 

Mantel

18"

Underside of

Mantel Shelf

All minimum distances are in inches

Log Sets

20"Manual background18”, 24”, 30”, and 36” Models

Top of Fireplace Opening

Figure 7 - Minimum Mantel Clearances When Using Hood