Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER Installation, Check Gas Type, Operation Only

Models: UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

1 24
Download 24 pages 28.18 Kb
Page 6
Image 6
INSTALLATION

VANGUARD FLAME-MAX™

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

NOTICE: A qualified service per- son must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

CHECK GAS TYPE WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali-

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 3 through 5.

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND

CLEARANCES (Vent-Free

Operation Only)

LOG SIZING REQUIREMENTS

Log

Minimum Firebox

Size

Height

Depth

Front Width

18"

17"

14"

20"

24"

17"

14"

26"

30"

17"

14"

32"

36”

17”

14”

38”

 

 

 

 

Carefully follow the instructions below. This will ensure safe installation into a masonry, U.L. listed manufactured fireplace, or AGA design certified vent-free firebox listed for use with these models.

Minimum Wall and Ceiling Clearances (see Figure 4)

fied chimney cleaner. Creosote will ignite if highly heated. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.

INSTALLATION AND WARNING: Seal any fresh air vents or ash clean-out doors lo- cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

Operation Only) WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 9)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

LOG SIZING REQUIREMENTS CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater

Minimum Wall and Ceiling Clearances (see Figure 4)WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE

CLEARANCE

TO COMBUSTIBLE

MATERIALS

Log Size

Side Wall

Ceiling

 

 

 

18", 24",

16"

42"

30”, and 36"

 

 

16"

Left and Right

Sides

A.Clearances from the side of the fire- place opening to any combustible wall should not be less than 16 inches.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

42"

where impurities in the air (such as tobacco smoke) exist, may discolor walls.

Figure 4 - Minimum Clearance to Wall and Ceiling

6

104256

Page 6
Image 6
Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER Installation, Check Gas Type, INSTALLATION AND CLEARANCES Vent-Free