VANGUARD FLAME-MAX™
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
NOTICE: A qualified service per- son must install heater. Follow all local codes.
NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali-
IMPORTANT:
CHECK GAS TYPE
Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION AND
CLEARANCES (Vent-Free
Operation Only)
LOG SIZING REQUIREMENTS
Log | Minimum Firebox | ||
Size | Height | Depth | Front Width |
18" | 17" | 14" | 20" |
24" | 17" | 14" | 26" |
30" | 17" | 14" | 32" |
36” | 17” | 14” | 38” |
|
|
|
|
Carefully follow the instructions below. This will ensure safe installation into a masonry, U.L. listed manufactured fireplace, or AGA design certified
Minimum Wall and Ceiling Clearances (see Figure 4)
fied chimney cleaner. Creosote will ignite if highly heated. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.
WARNING: Seal any fresh air vents or ash
WARNING: Never install the heater
•in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 9)
•in a recreational vehicle
•where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
•in high traffic areas
•in windy or drafty areas
CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater
WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE
CLEARANCE
TO COMBUSTIBLE
MATERIALS
Log Size | Side Wall | Ceiling |
|
|
|
18", 24", | 16" | 42" |
30”, and 36" |
|
|
16"
Left and Right
Sides
A.Clearances from the side of the fire- place opening to any combustible wall should not be less than 16 inches.
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
42"
where impurities in the air (such as tobacco smoke) exist, may discolor walls.
Figure 4 - Minimum Clearance to Wall and Ceiling
6 | 104256 |