OPERATIng fireplace
Continued
Thermostat Series Model HRC200
The
Digital Display Shows
Temperature and Settings
2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.
Key Pad Lock Feature
This feature allows the user to lock/unlock the keypad on the
Locks System to Prevent Accidental Ignition
Turns Burners
On or Off
Increases or Decreases Room Temperature in AUTO Mode
|
|
| Turns | |
| AUTO | Remote On or Off | ||
TEMP | and Allows You to | |||
| TEMP | |||
ROOM |
| SET |
| |
|
|
| Choose the Manual | |
LOCK | TEMP | POWER | Setting | |
MANU | ºC/ºF | AUTO |
| |
|
|
| ||
|
|
| Selects | |
|
|
| AUTO Mode | |
|
|
| °C/°F Mode Button |
Operating optional GWMT1
Wall Mounted Thermostat
WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.
Light the fireplace as instructed in Lighting Instructions on page 21. Set wall thermostat to desired temperature.
This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.
Upon installation, the thermostat must be allowed to stabilize
Figure 54 - Thermostat Hand-Held Remote Control Unit
Manual Mode | HRC200 |
|
1.Press the POWER and LOCK buttons together to turn on the
2.Press the MANU button to turn on the fireplace.
3.Press the POWER and LOCK buttons together to turn off the fireplace.
Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons together to turn on the
2. Press AUTO button to select this mode.
3. Set the desired room temperature by pressing the TEMP + or - buttons.
4. Press the POWER and LOCK buttons together to turn off the fireplace
Note: Do not leave the
Note: Do not hold the
Safety Features
When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fire- place, the receiver ON/OFF/REMOTE switch should be in the OFF position.
Auto Shutoff Feature
1.If the average room temperature exceeds 82° F (28° C), the
at room temperature for a minimum of 30 minutes for proper operation.
To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.
IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.
operating optional blower accessory
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel.
The BK manual blowerand the
Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time.The fireplace may run forseveral minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Peri- odically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.
www.desatech.com | 23 |