OPERATIng fireplace

Continued

11.Turn on all electric power to the fireplace.

12.Turn gas control knob counterclockwise to ON.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

 

Gas Control

 

 

Variable Control Knob

 

 

 

 

 

Knob

 

 

 

Piezo

 

IL

 

 

Ignitor

O

OT

O

 

 

P

IH

 

F

F

 

 

 

 

 

 

N

 

 

 

 

LO

Figure 51 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

1. Open lower louver panel.

OpTIONAL Hand-Held

REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 29). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, page 21.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 52). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

2.

Set selector switch in the OFF position to prevent draining

3.

battery.

Turn off all electrical power to the appliance if service is to

 

be performed.

Blower Control Knob (Optional Accessory)

Variable Control Knob

4.

Push in gas control knob slightly and turn clockwise

5.

to OFF.

Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

OFF

REMOTE

OFF

ON

Selector Switch in Remote Position

ON

N

 

 

O

 

L

 

 

 

 

T

 

O

I

L

 

O

H

O

 

 

 

I

F

 

 

P F

 

Gas Control Knob in ON Position

1. Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 19.)

2.Follow steps 1 through 8 under Lighting Instructions, page 21.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Follow steps 9 through 12 under Lighting Instructions, page 21.

5.Replace glass door (see Removing/Replacing Glass Door, page 19).

Figure 52 - Setting the Selector Switch, Gas Control Knob

and Variable Control Knob for Remote Operation

On/Off Series Model HRC100

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 53).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Indicator

LightControl

Button

Figure 53 - On/Off Hand-Held Remote Control Unit HRC100