Shutting Off Heater

OPERATING HEATER (REMOTE-READY MODELS)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Remote Control Operation

15

OPERATING HEATER

Continued

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, column 2.

Pilot

Ignitor

Pilot

Ignitor

Electrode

Burner

Burner

Electrode

 

 

 

 

 

Selector Switch in

 

 

 

Control Knob

OFF Position

 

 

 

 

 

 

 

 

 

 

 

 

Fireplace

 

F

 

 

 

Remote

F

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

O

AUTO

 

 

 

 

L

 

 

 

 

 

OFF

 

 

 

 

HI

ON

 

 

 

 

Off

Remote

On

 

 

 

Ignitor Button

 

Flame Adjustment Knob

 

 

 

Remote Control

Figure 18 - Control Knob and Ignitor Button Location, Remote Controlled

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8, pages 14 & 15.

9.Slightly push in and turn control knob counterclockwise Shutting Off Burner Only (pilot stays lit) to the ON position.

10.Wait one minute and switch selector switch to the ON po- sition to light burners. Note: AUTO is only functional when using GWMT1 or GWMS2 optional accessories.

11.Set flame adjustment knob to any level between HI and LO.

Figure 19 - Pilot (Propane/LP)

Pilot (Natural)

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Remote Control Operation to the OFF po- sition.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise Manual background to the PILOT po- sition.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 14.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, column 1.

REMOTE CONTROL OPERATION

Remote Control Operation

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Manual backgroundWARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit.

Manual backgroundManual backgroundManual backgroundFor more information, visit www.desatech.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111826-05

Page 15
Image 15
Desa VF-24N-EMU, VF-18P-EMU Operating Heater, Continued, Shutting Off Heater, Shutting Off Burner Only pilot stays lit