INSTALLATION
INSTALLATION |
| |
9 | ||
Mantel Clearances | ||
Floor Clearances |
| |
|
|
Continued
MANTEL CLEARANCES
Inadditiontomeetingnoncombustiblematerialclearances,youmustalso meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).
Determining Minimum Mantel Clearance When Using a Hood
If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using hood.
|
|
| Mantel Shelf |
|
| 10" |
|
|
|
| 8" |
|
|
|
| 6" |
|
|
|
| 2 1/2" |
|
|
|
Minimum Non- | (A) |
|
|
|
Combustible |
|
|
| |
|
|
|
| |
Material | 12" | 18" | 20" | 22" |
| ||||
| 8" | 14" | 17" | 19" |
| Minimum Non- | Distances to | ||
| Combustible |
| Underside of | |
| Material Height | Mantel |
|
Underside of
Mantel Shelf
All minimum distances are in inches
Log Set
24" 24" Models
20" 18" Model
Top of Fireplace
Opening
Figure 6 - Minimum Mantel Clearances Without Using Hood
NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation.Walls and man- tels above the firebox may become hot to the touch. If installed properly, these temperatures meet the re- quirement of the national product standard.Follow all minimum clearances shown in this manual.
NOTICE: If your installation does not meet the min- imum clearances shown, you must do one of the following:
•operate the logs only with the flue damper open
•raise the mantel to an acceptable height
•remove the mantel
FLOOR CLEARANCES
Minimum Non-
Combustible
Material
12" | Mantel Shelf |
| |
|
|
| |
10" |
|
|
|
8" |
|
|
|
6" |
|
|
|
2 1/2" |
|
|
|
8" | 12" | 15" | 18" |
| |||
Min. |
|
|
|
Hood | Distances to |
(GA6050,GA6052, | Underside of |
or GA6052) | Mantel |
Underside of
Mantel Shelf
All minimum distances are in inches
Log Set
20"
Top of Fireplace
Opening
A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).
Figure 7 - Minimum Mantel Clearances When Using Hood
| Combustible |
|
|
14" | Material | Hearth | Combustible |
| |||
Min. |
|
| |
|
|
| Material |
|
| 5" |
|
| Min. |
| |
|
|
| |
| Material |
|
|
Figure 8 - Minimum Fireplace | Figure 9 - Minimum Fireplace | ||
Clearances If Installed at Floor | Clearances Above |
| |
Level |
| Combustible Flooring |
For more information, visit www.desatech.com