Desa VF-24N-EMU, VF-18P-EMU, VF-18N-EMU Troubleshooting, Observed Problem, Possible Cause, Remedy

Models: VF-18N-EMU VF-18P-EMU VF-24P-EMU VF-24N-EMU

1 32
Download 32 pages 6.97 Kb
Page 19
Image 19
TROUBLESHOOTING

TROUBLESHOOTING

19

TROUBLESHOOTING

Note: For additional help, visit DESA technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: �Turn off and un- plug heater and let cool before servicing.Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to ignitor

1.

Reconnect ignitor cable

spark at ODS/pilot

 

cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned wrong or

6.

Replace pilot assembly for remote-ready

 

 

broken

 

units; Replace ignitor electrode for vari-

 

 

 

 

able manually controlled units

 

 

 

 

 

 

When ignitor button is pressed, there is spark

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply (propane/LP

5.

Contact local propane/LP gas company

 

 

only)

 

 

 

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18) or replace

 

 

 

 

ODS/pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long

2.

After ODS/pilot lights, keep control

 

 

enough

 

knob pressed in 30 seconds

 

3.

Safety interlock system has been

3.

Wait one minute for safety interlock sys-

 

 

triggered

 

tem to reset. Repeat ignition operation

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

5.

Pilot flame not touching thermocouple,

5.

A) Contact local natural or propane/LP

 

 

which allows thermocouple to cool,

 

gas company

 

 

causing pilot flame to go out. This prob-

 

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

the following:

 

Maintenance, page 18) or replace ODS/

 

 

A) Low gas pressure

 

pilot assembly

 

 

B) Dirty or partially clogged ODS/

 

 

 

 

 

pilot

 

 

 

 

6.

Thermocouple connection loose at con-

6.

Hand tighten until snug, then tighten

 

 

trol valve

 

1/4 turn more

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve