Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD Installation, Operating Heater, Continued

Models: VF-24N-PJD

1 32
Download 32 pages 60.09 Kb
Page 14
Image 14
Figure 15 - Checking Gas Joints for

INSTALLATION

Continued

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 13).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP sup- ply to equipment shutoff valve for propane/LP (see Figure 14 or 15). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

 

Open

 

Shutoff Valve

 

 

Propane/LP

Equipment Shutoff Valve

Supply Tank

 

Control Valve Location

Figure 15 - Checking Gas Joints for

Propane/LP Gas

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 13).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 14 or 15). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appli- ance, page 17 or 18).

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

Closed

 

Figure 13 - Equipment Shutoff Valve

WARNING: If you do not fol-

Equipment Shutoff Valve

low these instructions exactly,

a fire or explosion may result

 

causing property damage, per-

 

sonal injury or loss of life.

Gas Meter

A. This appliance has a pilot which must be

 

lighted by hand. When lighting the pilot,

 

follow these instructions exactly.

 

B. BEFORE LIGHTING smell all around the

 

appliance area for gas. Be sure to smell next

Control Valve

to the floor because some gas is heavier than

air and will settle on the floor.

Location

 

Figure 14 - Checking Gas Joints for

Natural Gas

14

www.desatech.com

111826-04A

Page 14
Image 14
Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD Installation, Operating Heater, Continued, Checking Gas Joints for