REMOTE LIGHTING

OPERATING HEATER

Continued

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

REMOTE LIGHTING

INSTRUCTIONS

Manual background WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

You must operate this heater withafireplacescreeninplace. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Manual background CAUTION: A mild gas flash within 10 seconds is normal during shutdown of this heater. Remain clear of the hearth area for the entire shutdown process to avoid possible injury.

1.STOP! Read the safety information begin- ning on page 14.

2.Make sure equipment shutoff valve is fully open.

3.Turn motor knob clockwise Manual background to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 14. If you donʼt smell gas, go to the next step.

5.Make sure ON/OFF switch is in "–" (ON) position.

Manual background WARNING: Burner will come on automatically within one min- ute after pilot burner is lighted.

6.Press the buttons Manual background and Manual background at the same time. A short acoustic signal confirms the start sequence has begun.

Further short acoustic signals (0.2 sec., 1 Hz) indicate the ignition process until it is com- pleted and main gas flows. If pilot is already lit, motor will turn on (max. flame height) while buttons are pressed down. If pilot does not light, see Troubleshooting, page 20.

7.Press Manual background to turn on main burner and in-

crease flame height. Press to decrease flame height and shut off main burner.

8.Short tapping of either button allows incre- mental change in flame height.

9.Press OFF button to switch off main gas and pilot gas.

FUNCTIONS OF

REMOTE CONTROL

Battery

After the charged battery has been correctly installed, the remote hand set is ready for operations.

Remove the battery if the remote handset will not be used more than one year.

111826-04A