OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from paint,

1.

Open window to ventilate

odors

 

hair spray, glues, cleaners, chemi-

 

room. Stop using odor caus-

 

 

cals, new carpet, etc. (See IM-

 

ing products while heater is

 

2.

PORTANT statement above)

2.

running

 

Low fuel supply (propane/LP

Refill supply tank (propane/LP

 

3.

only)

3.

only)

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

2.

able

2.

ventilation

 

Low line pressure

Contact local natural or pro-

 

3.

ODS/pilot is partially clogged

3.

pane/LP gas company

 

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 26)

 

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

2.

Control valve or gas control

2.

tions, page 16)

 

Replace control valve or gas

 

 

defective

 

control

 

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

2.

trol valve and burner

2.

remove foreign matter

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

 

 

 

 

 

Log set cycles to pilot, but room

1.

Hand-held remote control is

1.

Move hand-held remote con-

temperature drops to a lower

 

too close to heater

 

trol unit farther away from the

than ideal level before log set

 

 

 

heater

comes back on

 

 

 

 

 