Installation |
Continued |
Equipment |
Shutoff Valve |
Gas Meter |
Thermostat Gas |
Valve or Control |
Valve Location |
Figure 17 - Checking Gas Joints (Natural
Gas Only)
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve (see Figure 15, page 15).
2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP sup- ply to equipment shutoff valve for propane/LP (see Figure 16, page 16 or Figure 17). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 19). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appli- ance, page 21.
Installing optional remote accessories
Installing Remote Receiver
Remote control accessories are available sepa- rately (see Accessories, page 33).
1.If unit is already installed in fireplace, continue with these instructions. If unit has not been installed in fireplace, go to step 6 and continue installation of remote accessory.
WARNING: Turn off heater and let cool before handling any part of heater. Make sure gas is turned of to unit.
2.Carefully remove logs and set aside.
3.Locate mounting screws on sides of heater base assembly and remove screws. Set screws aside for reinstallation.
4.Disconnect gas line from heater base as shown in Figure 11, page 13.
WARNING: A qualified ser- vice person must connect and disconnect gas to heater. Follow all local codes.
5.Remove heater base from fireplace.
6.Install receiver bracket to base with phillips screws provided in hardware kit as shown in Figure 18.
7.If installed, disconnect AUTO/OFF/ON switch wire from control valve at TPTH and TH locations (see Figure 19, page 17).
8.Install remote receiver into receiver bracket using pads and push button clips provided with receiver (see Figure 18).
Terminal | ||
Battery | ||
Wires | ||
Battery | ||
Pads | ||
Clip |
Remote
Receiver
Bracket
Push
Button
Clips
Electronic Ignitor
(On Base Assembly)
Figure 18 - Installing Remote Receiver
Bracket
Switch
Control
Valve
Figure 19 - Disconnecting Switch from
Control Valve
16 | www.desatech.com |