Desa VGC18NR/PR Product Identification, Local Codes, Unpacking, Product Features, Operation

Models: VGC18NR/PR

1 36
Download 36 pages 796 b
Page 5
Image 5
Product

Product

Identification

Electronic

Ignitor

Chassis

 

Glowing

 

 

Embers

 

 

Flame

Control

Remote

Adjustment

Knob

Control

Knob

AUTO/

(Optional)

 

 

 

OFF/ON

 

 

Switch

Figure 1 - Product Identification

Local Codes

Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269Optional Remote Control

Accessories

There are four optional remote controls that

can be purchased separately for Remote-Ready

Models Only:

 

 

wall switch

hand-held ON/OFF remote

wall thermostat

hand-held thermostat remote

See Accessories, page 42.

The wall thermostat or hand-held thermostat may not be used where vented decorative listing is required.

Unpacking

Figure 1 - Product Identification CAUTION: Do not remove the data plates from the grate as- sembly. The data plates contain important warranty and safety information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base as- sembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Product Features

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for vent-free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening the flue damper.

Safety Device

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Electronic Ignition System

This heater has an electronic ignitor to light heater fuel supply.

119162-01Awww.desatech.com

Page 5
Image 5
Desa VGC18NR/PR Product Identification, Local Codes, Unpacking, Product Features, Operation, Safety Device