Desa (V)KC42N Series, (V)KC42P SERIES REMOVING/REPLACING Glass Door, Installing Remote Receiver

Models: (V)KC42N Series (V)KC42P SERIES

1 40
Download 40 pages 6.59 Kb
Page 21
Image 21

FIREPLACE INSTALLATION

Installing Optional Wireless Hand-Held Remote Control - GHRCB and GHRCTB Series Removing/Replacing Glass Door

21

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37).

4.Attach the terminal wires to the battery.

5.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).

6.Replace the switch bracket.

Receiver

9-Volt Alkaline

Battery

Terminal Wires

Battery Clip

Figure 37 - Attaching Alkaline Battery to Receiver

To Optional

Remote

Accessory

Figure 38 - Control Valve Terminals

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Battery Cover

Remote Control Unit

Terminal

 

Wires

 

9-Volt

 

Alkaline

Battery

Battery

Housing

 

Figure 39 - Installing Alkaline Battery in Hand-Held Remote

Control Unit (GHRCB)

 

9-Volt

Terminal

Wires

Battery

Remote

 

 

Control

 

Unit

 

Battery

 

Cover

Figure 40 - Installing Battery in Hand-Held Remote Control Unit

(GHRCTB Series)

 

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a

broken glass door panel or without the glass door

panel securely in place. For replacement part infor-

mation see Replacement Parts, page 31.

CAUTION: Wear gloves and safety glasses while

handling or removing broken glass. Do not remove if

glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn

off and unplug fireplace. Let cool before removing

glass door or louvers.

 

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling

both top end spring latches towards the center of the appliance until

they are disengaged from the locating holes (see Figure 41). Repeat

for bottom spring latches and pull the louvers outward. To install or

replace items removed, simply reverse the procedures above.

Louver Panel

Spring Latch

Figure 41 - Removing Louver Panel

116239-01B

www.desatech.com

Page 21
Image 21
Desa (V)KC42N Series, (V)KC42P SERIES REMOVING/REPLACING Glass Door, Installing Remote Receiver, Removing Louver Panels

(V)KC42N Series, (V)KC42P SERIES specifications

The Desa (V)KC42P SERIES and (V)KC42N Series represent a significant advancement in the field of heating solutions, designed to enhance comfort while optimizing energy efficiency. These innovative heating systems are engineered for residential and commercial applications, making them versatile for various environments.

One of the standout features of the Desa (V)KC42P and (V)KC42N Series is their advanced control technologies. Equipped with smart thermostatic controls, these units allow users to manage their heating needs with precision. The intuitive user interface provides an easy way to adjust settings, ensuring that the desired temperature is achieved while minimizing energy consumption.

The efficiency of the (V)KC42P and (V)KC42N Series is further enhanced by their state-of-the-art combustion technology. These models utilize a unique burner design that maximizes heat output while reducing emissions. This not only supports environmental sustainability but also ensures that users save on energy costs without compromising performance.

Safety is another paramount feature of these heating systems. The Desa series incorporates multiple fail-safes, including overheat protection and automatic shut-off mechanisms. These features are designed to provide peace of mind for users, knowing that their home or business is equipped with a system that prioritizes safety.

Durability and reliability are also hallmarks of the Desa (V)KC42P and (V)KC42N Series. Constructed with high-quality materials, these units are built to withstand the rigors of daily use while maintaining an aesthetically pleasing design. This ensures they complement any décor while delivering consistent performance across seasons.

In terms of installation, both series come with flexible options. They can be easily integrated into existing setups, making upgrades or replacements hassle-free. The user-friendly installation procedures reduce downtime, allowing users to enjoy the benefits of their new heating system almost immediately.

Additionally, the (V)KC42P and (V)KC42N Series are designed with versatility in mind. They can accommodate various heating methods, from forced air to radiant heating, making them suitable for different heating preferences and system requirements.

In summary, the Desa (V)KC42P and (V)KC42N Series are engineered to provide superior heating performance, energy efficiency, and safety. With advanced technology, durable construction, and user-friendly features, these heating solutions stand out in the market as reliable options for any heating need.