Safety information

Continued

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

3.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

4.Turn fireplace off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annually by a qualified service person.

5.You must keep control compartments, burn- ers and circulating air passages clean. More frequent cleaning may be needed due to ex- cessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

6.Have venting system inspected annually by a qualified service person. If needed, have vent- ing system cleaned or repaired. See Cleaning and Maintenance, page 30.

7.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate.

8.This appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

9.Do not use fireplace if any part has been ex- posed to or under water. Immediately call a qualified service person to arrange for replace- ment of the unit.

10.Do not operate fireplace if any log is broken.

11.Do not operate fireplace with glass door removed, cracked or broken.

12.Provide adequate clearances around air openings.

 

Product

 

Identification

Upper Louver

Panel

Flue Collar

Nailing

Log

Set

Flange

 

Glass

Door

Assembly

Lava

Rock

Lower

Louver

Panel

Glowing Burner

Electronic Embers Assembly Control Valve

Andiron

Switch Bracket for Optional Assembly Remote and Blower

Figure 1 - Direct-Vent Fireplace with

Millivolt Ignition

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the cur- rent National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

www.desatech.com116240-01E