OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep con- trol areas, burner, and circulating air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fied service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 35).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 36). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 35 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet

Hole

Pilot Assembly

Figure 36 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burner will produce flames and soot

fireplace will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

You can also visit DESA International’s technical services web site at

www.desatech.com.

104407

23

Page 23
Image 23
Desa VMH10TPA installation manual Cleaning and Maintenance, Service Hints, Technical Service, Cabinet

VMH10TPA specifications

Desa VMH10TPA is a versatile and innovative heating solution designed to meet the demands of modern living environments. This gas-powered heater is part of a broader trend towards efficient, reliable, and user-friendly heating systems that cater to both residential and commercial spaces. With its robust construction and advanced features, the VMH10TPA stands out in the market as a dependable option for those looking to maintain a comfortable atmosphere during the colder months.

One of the main features of the Desa VMH10TPA is its efficiency. The heater boasts a high heating capacity while consuming minimal gas, making it economical for users concerned about energy costs. It is designed to provide consistent warmth while adhering to strict environmental standards, ensuring that installations comply with local regulations concerning emissions and energy use. The unit's design includes a state-of-the-art burner system that maximizes heat distribution, ensuring that rooms are warmed quickly and evenly.

In terms of technology, the VMH10TPA utilizes advanced electronic ignition systems. This feature not only simplifies the ignition process but also enhances safety by reducing the risk of gas leaks associated with manual lighting methods. Additionally, the heater is equipped with temperature control settings, allowing users to customize their heating experience according to their needs.

Another notable characteristic is its compact and aesthetically pleasing design. The VMH10TPA is engineered for easy installation, with options for both wall-mounted and free-standing configurations. Its sleek appearance allows it to blend seamlessly into various interior decors without being an eyesore.

Safety is a paramount consideration in the design of the Desa VMH10TPA. The heater is outfitted with multiple safety features, including automatic shut-off mechanisms that activate in the event of a malfunction or abnormal operation, providing peace of mind to users.

In summary, the Desa VMH10TPA is an efficient, technologically advanced, and user-friendly heating solution. With its combination of high performance, safety features, and stylish design, it caters to a wide range of heating needs, making it an excellent choice for anyone seeking a reliable heater. As energy efficiency and user safety continue to be top priorities, the Desa VMH10TPA represents a significant step towards achieving these goals in home heating technology.