OPERATING FIREPLACE
Continued
7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.
•If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs.
8.Turn control knob counterclockwise
to desired heating level. The burn- ers should light. Set control knob to any heat level between HI and LO.
CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.
Ignitor Electrode | Pilot Burner |
Figure 29 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
Turn control knob clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise to the PILOT position.
THERMOSTAT
CONTROL OPERATION
You can set the thermostat control knob to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat out- put and flame height from higher to lower set- tings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Note: Selecting the HI setting will cause the burner to remain on without modulating down in most cases.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Lighting In- structions, page 17.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.
BLOWER
OPERATION
WARNING: This fireplace has a
Locate the blower switch by opening lower lou- ver on fireplace. Blower switch is located at lower left inside louver door.
This
Note: It is safe to operate fireplace with blower turned off. However, the blower helps distrib- ute heated air from the fireplace.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other ob- structions.
18 | www.desatech.com |