INSTALLATION
Continued
9.If blower is installed, route blower electrical cord through access holes in either side of fire- place. Note: Bushing may be moved if neces- sary. Plug electrical cord into electrical outlet.
10.Carefully insert fireplace into cabinet mantel (Figure 12). Be careful not to scratch or dam- age hearth base, cabinet mantel, or any lami- nate trim on hearth base. Remove protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fire- place to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.
11.Attach gas line from fireplace gas regulator to gas supply. See Connecting Fireplace to Gas Supply, page 14.
12.Check all gas connections for leaks. See Checking Gas Connections, page 15.
Cabinet
Mantel
Figure 12 - Inserting Fireplace Into
Cabinet Mantel
BUILT-IN FIREPLACE INSTALLATION
12.Follow the instructions below to install the fire- place in this manner.
| Actual | Framing |
Height | 32 3/8" | 33" |
Front Width | 34 5/16" | 35 1/2" |
Depth | 16 11/16" | 17 3/4" |
1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough opening. If installing in a corner, use dimensions shown in Figure 14 for the rough opening. The height is 33" which is the same as the wall opening above.
Figure 10 - Installing Cabinet Mantel
17 3/4"
33"
35 1/2"
Figure 13 - Rough Opening for Installing
Nailingin Wall
Flanges
39 3/8"
27 7/8"
35 1/2" 55 5/8"
Figure 11 - Location of Nailing Flanges
Figure 14 - Rough Opening for Installing
in Corner
www.desatech.com | 11 |