Desa VSGF36NRB, VSGF36PTB Continued, Hard-wiringFirebox, Installing Fireplace Hood And Screen

Models: VSGF36NRB VSGF36NTB VSGF36PRB VSGF36PTB

1 40
Download 40 pages 5.35 Kb
Page 18
Image 18
Hard-wiring Firebox

Installation

Continued

Hard-wiring Firebox

NOTICE: A qualified electrician must connect electrical wiring to duplex outlet for built-in instal- lation. Follow all local codes. In absence of local codes fol- low The National Electric Code ANSI/NFPA 70.

The “Handy Box” with duplex outlet is provided in the firebox located in the lower right base area.

1.Remove screw holding duplex outlet cover to handy box. Remove duplex outlet.

2.Route electrical cable through strain relief and handy box (see Figure 23). Tighten screws on strain relief.

3.Connect electrical cable to duplex outlet. Match wire colors to those on duplex outlet. Be sure to connect the ground wire.

4.Place duplex outlet back into handy box and secure with screws. Replace outlet cover.

Duplex Box/

Handy Box

Screws

Strain Relief

Figure 23 - Hard-Wiring Firebox

INSTALLING FIREPLACE HOOD AND SCREEN

1.Loosen screws inside top edge of firebox. Slide notches in hood over screws and tighten screws (see Figure 24).

2.Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 25).

Screw

Hood

Figure 24 - Hood Placement

(Model May Vary From Illustration)

Screw

Screen

Figure 25 - Screen Placement

(Model May Vary From Illustration)

18

www.desatech.com

119305-01A

Page 18
Image 18