Desa VSGF36NRB Continued, Observed Problem, Possible Cause, Remedy, see Checking Gas Connec

Models: VSGF36NRB VSGF36NTB VSGF36PRB VSGF36PTB

1 40
Download 40 pages 5.35 Kb
Page 30
Image 30
(see Checking Gas Connec-

Troubleshooting

Continued

stalling Logs, page 17) WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

 

Fireplace produces unwanted

1.

Heater burning vapors from

1.

Open window to ventilate

odors

 

paint, hair spray, glues, cleaners,

 

room. Stop using odor caus-

 

 

 

chemicals, new carpet, etc. (See

 

ing products while heater is

 

 

2.

IMPORTANT statement above)

2.

running

 

 

Low fuel supply (propane/LP

Refill supply tank (propane/LP

 

 

3.

only)

3.

only)

 

 

Gas leak. See Warning

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 16)

Fireplace shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

 

operates)

2.

able

2.

ventilation

 

 

Low line pressure

Contact local natural or pro-

 

 

3.

ODS/pilot is partially

3.

pane/LP gas company

 

 

Clean ODS/pilot (see Cleaning

 

 

 

clogged

 

and Maintenance, page 25)

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

 

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

2.

Control valve or gas control

2.

tions, page 16)

 

 

Replace control valve or gas

 

 

 

defective

 

control

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

 

2.

trol valve and burner

2.

remove foreign matter

 

 

Gas leak. See Warning

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 16)

Dark residue on logs inside

1.

Improper log placement

1.

Properly locate logs (see In-

 

of their fireplace. Note: After

2.

Drafts or other air currents

2.

stalling Logs, page 17)

removing all causes of residue

Eliminate source of drafts

deposits, completely clean fire-

3.

affecting flame pattern

3.

around heater

place and appliance off residue

Air holes at burner inlet

Clean out air holes at burner

before reusing appliance

 

blocked

 

inlet. Periodically repeat as

 

 

4.

Burner flame holes blocked

4.

needed

 

 

Remove blockage

 

Log set cycles to pilot, but room

1.

Thermostat sensing bulb needs

1.

Reposition thermostat sensing

 

temperature drops to a lower

 

to be repositioned (Thermo-

 

bulb

than ideal level before log set

2.

stat-Controlled Models Only)

 

 

 

 

comes back on

Hand-held remote control is

2.

Move hand-held remote control

 

 

 

too close to heater (Remote-

 

 

 

 

unit farther away from the heater

 

 

 

Ready Models Only)

 

 

 

 

 

 

 

 

30

www.desatech.com

119305-01A

Page 30
Image 30
Desa VSGF36NRB Continued, Observed Problem, Possible Cause, Remedy, see Checking Gas Connec, and Maintenance, page