6

LOCATION OF TERMINATION CAP

LOCATION OF TERMINATION CAP

N

N

D

E V

B L

C

Fixed

 

V

Closed

 

 

 

Openable

 

F V

Openable

B

Fixed

Closed

H

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum]

B= clearance to window or door that may be opened

[12 inches (305mm) minimum]

C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum]

E= clearance to unventilated soffit [12 inches (305mm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (914mm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (1829mm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (305mm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (1829mm) minimum]

L= clearance above paved side-walk or a paved driveway located on public property [*84 inches (2133mm) minimum]

M= clearance under veranda, porch, deck [*12 inches (305mm) minimum ]

N= clearance above a roof shall extend a minimum of 24 inches (610mm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow

the current National Fuel Gas Code, ANS Z223.1

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

A

 

 

 

A = 6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B B = 6" (152mm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = 12" (305mm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (610mm)

J = 20" (508mm)

C = Maximum depth of 48" (1219mm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (610mm)

E = Clearance from corner in recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm)

Figure 7 - Minimum Clearances for Termination Cap

For..com

108860

Page 6
Image 6
Desa (V)T36EN SERIES, (V)T32EP, (V)T36EP SERIES, V)T32EN Location of Termination CAP, Balcony with Perpendicular Side Wall

(V)T32EP, V)T32EN, (V)T36EP SERIES, (V)T36EN SERIES specifications

The Desa (V)T36EP Series, (V)T32EP, (V)T36EN Series, and (V)T32EN represent a significant advancement in heating technology, designed to deliver efficient warmth and comfort in various environments. These models are notable for their innovations, user-friendly features, and durability, making them a popular choice among consumers seeking effective heating solutions.

One of the main features of the Desa (V)T36EP and (V)T32EP models is their energy efficiency. Engineered with advanced combustion systems, these units optimize fuel usage, translating to lower energy bills while maintaining superior heating performance. The energy efficiency ratings of these models are impressive, making them not only environmentally friendly but also cost-effective in the long run.

The (V)T36EN and (V)T32EN series offer similar energy-efficient heating solutions without compromising on output capacity. Both series employ a robust design that ensures consistent performance even in colder climates. The built-in thermostat and multiple heat settings allow users to customize their heating experience, ensuring maximum comfort geared to individual preferences.

Technologically, the Desa models boast a range of innovative features. The automatic shut-off function promotes safety by turning the unit off when it reaches an unsafe temperature or if it tips over. This feature is crucial for families with children and pets, providing peace of mind. Additionally, the user-friendly controls make adjusting settings straightforward, further enhancing the user experience.

Durability is another key characteristic of the Desa (V)T36EP, (V)T32EP, (V)T36EN, and (V)T32EN series. Constructed from high-quality materials, these units are designed to withstand the rigors of daily use. The stylish yet practical design allows them to blend seamlessly with various decors while providing reliable heating.

Furthermore, the models in this series are designed for ease of maintenance. The accessible filters and components make routine cleaning simple, ensuring the units operate efficiently over their lifespan.

In conclusion, the Desa (V)T36EP SERIES, (V)T32EP, (V)T36EN SERIES, and (V)T32EN models represent a perfect blend of efficiency, safety, and durability, catering to modern heating needs. Their advanced features and technologies provide an excellent solution for consumers looking for long-lasting and reliable heating options in any living space.