18

FIREPLACE INSTALLATION

Installing Optional Blower Accessories (Cont.)

FIREPLACE INSTALLATION

Continued

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorpo- rated onto the blower housing (see Figure 28).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight.

5.Mount the speed control box against the mounting plate pro- vided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 26, page 17).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise un- til it is tight against mounting plate. Place control knob pro- vided on shaft (see Figure 26, page 17).

7.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire rout- ing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be ad- justed by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27, page 17).

Power Cord

White Wire

Blue Wire Magnetic

Thermal

Strips

Switch

Air Flow

Bracket

Black

Direction

 

Wire

 

Phillips

 

Screw

 

Thermal Switch

Ring Terminal

on Green Wire

 

Air Flow Direction

 

Magnets

Route BKT

 

Blower Through

Thermodisc

This Area

 

Side View Firebox Bottom

Blower

Location

 

Figure 28 - Blower Model BKT

 

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2

Black

 

On

 

Blue

110/115

V.A.C.

Black

Blower

 

White

Motor

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models

For..com

108860

Page 18
Image 18
Desa (V)T36EN SERIES, (V)T32EP, (V)T36EP SERIES, V)T32EN installation manual Blower Wiring Diagram, Blower Model BKT

(V)T32EP, V)T32EN, (V)T36EP SERIES, (V)T36EN SERIES specifications

The Desa (V)T36EP Series, (V)T32EP, (V)T36EN Series, and (V)T32EN represent a significant advancement in heating technology, designed to deliver efficient warmth and comfort in various environments. These models are notable for their innovations, user-friendly features, and durability, making them a popular choice among consumers seeking effective heating solutions.

One of the main features of the Desa (V)T36EP and (V)T32EP models is their energy efficiency. Engineered with advanced combustion systems, these units optimize fuel usage, translating to lower energy bills while maintaining superior heating performance. The energy efficiency ratings of these models are impressive, making them not only environmentally friendly but also cost-effective in the long run.

The (V)T36EN and (V)T32EN series offer similar energy-efficient heating solutions without compromising on output capacity. Both series employ a robust design that ensures consistent performance even in colder climates. The built-in thermostat and multiple heat settings allow users to customize their heating experience, ensuring maximum comfort geared to individual preferences.

Technologically, the Desa models boast a range of innovative features. The automatic shut-off function promotes safety by turning the unit off when it reaches an unsafe temperature or if it tips over. This feature is crucial for families with children and pets, providing peace of mind. Additionally, the user-friendly controls make adjusting settings straightforward, further enhancing the user experience.

Durability is another key characteristic of the Desa (V)T36EP, (V)T32EP, (V)T36EN, and (V)T32EN series. Constructed from high-quality materials, these units are designed to withstand the rigors of daily use. The stylish yet practical design allows them to blend seamlessly with various decors while providing reliable heating.

Furthermore, the models in this series are designed for ease of maintenance. The accessible filters and components make routine cleaning simple, ensuring the units operate efficiently over their lifespan.

In conclusion, the Desa (V)T36EP SERIES, (V)T32EP, (V)T36EN SERIES, and (V)T32EN models represent a perfect blend of efficiency, safety, and durability, catering to modern heating needs. Their advanced features and technologies provide an excellent solution for consumers looking for long-lasting and reliable heating options in any living space.