Desa CGDV32NR VENTING INSTALLATION INSTRUCTIONS Continued, Recommended Applications

Models: (V)T32N-A Series (V)T32P-A Series

1 38
Download 38 pages 10.07 Kb
Page 11
Image 11
Manual background

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

11

VENTING INSTALLATION INSTRUCTIONS Continued

CORNER INSTALLATION

Recommended Applications:

Corner ground floor installation

Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe)

Basement installation where one foot clearance from ground to termination is possible

Vertical (V)

Required

 

Vertical Pipe

Horizontal (H)

*43

3

/4" min.

None

30" max.

 

53

3

/4" min.

1 ft.

48" max.

 

65

3

/4" min.

2 ft.

60" max.

 

77

3

/4" min.

3 ft.

84" max.

 

89

3

/4" min.

4 ft.

20' max.

 

* Ground Floor Corner Venting

 

 

 

 

 

Not to Exceed

Not to Exceed

(H) Limits

Square Termination

Wall

Firestop

90° Elbow

As Required for (V)

Manual background See Chart for Pipe

Section Required

45° Manual background Elbow

(H)Limits

90° Elbow Manual background

Wall

Firestop

45° Elbow

Square Termination

12" Minimum

Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° Elbow

SNORKEL TERMINATION INSTALLATION

Recommended Applications:

Installations requiring a vertical rise on building exterior

Any installation using snorkel termination to achieve one foot above ground

Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If install- ing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination.

Snorkel Termination

Snorkel Termination

12" Minimum

Figure 16 - Snorkel Termination Configurations for Below Ground

Snorkel

 

 

Wall

Termination

 

 

 

 

Firestop

90°

Elbow

 

12"

45°

 

Minimum

 

Elbow

 

 

 

Adequate

 

 

 

Drainage

 

 

 

Installation

12" Minimum

116646-01A

www.desatech.com

Page 11
Image 11
Desa CGDV32NR, (V)T32N-A Series, (V)T32P-A Series VENTING INSTALLATION INSTRUCTIONS Continued, Recommended Applications