5.

This fireplace reaches high temperatures. Keep children and

 

adults away from hot surfaces to avoid burns or clothing igni-

 

tion. Fireplace will remain hot for a time after shutdown. Allow

 

surfaces to cool before touching.

6.

Carefully supervise young children when they are in the room

 

with fireplace.

7.

Do not modify this fireplace under any circumstances. Any

 

parts removed for servicing must be replaced prior to operating

 

fireplace.

8.

Turn fireplace off and let cool before servicing, installing or

 

repairing. Only a qualified service person should install, service

 

or repair this fireplace. Have fireplace inspected annually by a

 

qualified service person.

9.

You must keep control compartments, burners and circulating

 

air passages clean. More frequent cleaning may be needed due

 

to excessive lint and dust from carpeting, bedding material, etc.

 

Turn off the gas valve and pilot light before cleaning fireplace.

10.

Have venting system inspected annually by a qualified service

 

person. If needed, have venting system cleaned or repaired. See

 

Cleaning and Maintenance, page 28.

11.

Keep the area around your fireplace clear of combustible ma-

 

terials, gasoline and other flammable vapor and liquids. Do

 

not run fireplace where these are used or stored. Do not place

 

items such as clothing or decorations on or around fireplace.

12.

Do not use this fireplace to cook food or burn paper or other

 

objects.

Upper Louver

Panel

Nailing

Flange

Glass

Door

Assembly

Piezo

Ignitor

Control

Valve

Lower

Louver Glowing

Panel Embers

ON/OFF/REMOTE Switch

(Optional Installation)

Flue Collar

Log

Set

Lava

Rock

Grate

Assembly

Blower Switch (Optional Installation)

13.

Do not use any solid fuels (wood, coal, paper, cardboard, etc.)

 

in this fireplace. Use only the gas type indicated on fireplace

 

nameplate.

14.

This appliance, when installed, must be electrically grounded

 

in accordance with local codes or, in the absence of local

 

codes, with the National Electrical Code, ANSI/NFPA 70 or

 

the Canadian Electrical Code, CSA C22.1.

15.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service person to arrange

 

for replacement of the unit.

16.

Do not operate fireplace if any log is broken.

17.

Do not use a blower insert, heat exchanger insert or other ac-

 

cessory not approved for use with this fireplace.

18.

Do not operate fireplace with glass door removed, cracked or

 

broken.

19.

Provide adequate clearances around air openings.

Figure 1 - Direct-Vent Fireplace with Millivolt Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

116646-01A

www.desatech.com

Page 3
Image 3
Desa (V)T32N-A Series, (V)T32P-A Series, CGDV32NR installation manual Safety Information Product Identification, Local Codes

CGDV32NR, (V)T32N-A Series, (V)T32P-A Series specifications

The Desa (V)T32N-A Series and (V)T32P-A Series, along with the CGDV32NR, represent a significant advancement in modern energy solutions, combining efficiency, durability, and innovative technologies to meet the evolving needs of consumers and businesses alike.

The (V)T32N-A Series is designed specifically for residential applications, featuring a compact and lightweight structure that enables easy installation in various settings. Its primary characteristic is its energy-efficient operation, which minimizes energy consumption while providing optimal heating performance. This series incorporates advanced heating technology, delivering uniform warmth and maximizing comfort in living spaces. The user-friendly digital control panel offers a range of settings, allowing users to customize their heating preferences with ease.

In contrast, the (V)T32P-A Series is tailored for commercial use, boasting a robust design that can withstand the demands of high-traffic environments. This series features enhanced output capacity and quicker heating response times, making it suitable for large venues such as offices, retail spaces, and warehouses. The Duracore technology employed in this series ensures that the heating system is not only powerful but also reliable, reducing downtime and maintenance costs.

The CGDV32NR offers a versatile solution that excels in both residential and commercial applications. Its standout feature is the dual-fuel capability, allowing users to choose between natural gas and propane. This flexibility provides an additional layer of convenience and adaptability, catering to diverse energy needs and preferences. Furthermore, the CGDV32NR is equipped with smart technology that integrates with home automation systems, enabling users to control their heating from a mobile device or smart home interface.

All three series incorporate safety features such as flame failure shut-off and overheat protection, ensuring peace of mind for users. The sleek designs and aesthetic options of the (V)T32N-A and (V)T32P-A Series allow them to blend seamlessly with various interior styles, while the CGDV32NR’s practical functionality and modern design make it an attractive option for any setting.

In summary, the Desa (V)T32N-A Series, (V)T32P-A Series, and CGDV32NR combine cutting-edge technology, energy efficiency, and user-friendly features to deliver ideal solutions for heating needs across residential and commercial landscapes. These series showcase Desa's commitment to innovation, sustainability, and customer satisfaction, marking a significant step forward in heating technology.