VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination

13

VENTING INSTALLATION INSTRUCTIONS

Continued

INSTALLATION FOR VERTICAL TERMINATION

Note: Vertical restrictor must be installed in all vertical installations.

1.Determine the route your vertical venting will take. If ceiling joists, roof rafters or other framing will obstruct the venting system, consider an offset (see Figure 19) to avoid cutting load bearing members. Note: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insu- lation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations.

2.Set the fireplace in desired location. Drop a plumb line down from the ceiling to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point.

Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point.

Roof Flashing

Wall Strap

45° Elbow

Ceiling Firestop

Figure 19 - Offset with Wall Strap and 45° Elbows

Flat Ceiling Installation

1.Cut a 10 3/4" square hole in the ceiling using the locating hole as a center point. The opening should be framed to 10 3/4"x10 3/4" (273 mm x 273 mm) inside dimensions, as shown in Figure 9 on page 8 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceiling or a room, nail firestop from the top side. This prevents loose insulation from falling into the required clearance space. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 20).

2.Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop. Be sure all pipe and elbow connections are fully twist-locked (see Figure 8, page 8).

3.Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof.) The 10 3/4"x10 3/4" hole must be measured on the horizontal; actual length may be larger depending on the pitch of the roof. There must be a 1" clearance from the vent pipe to combustible materials. Frame the opening as shown in Figure 9, page 8.

4.Connect a section of pipe and extend up through the hole.

Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 19). Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air.

5.Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing as shown in Figure 19. There must be a 1" clearance from the vent pipe to combustible materials.

6.Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements described in Figure 7 on page 6. Note: You must increase vent height for steep roof pitches. Nearby trees, adjoining rooflines, steep pitched roofs and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent height may solve this problem.

7.Twist-lock the vent cap onto the last section of vent pipe.

Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allow- able clearances to combustibles. Do not fill any of the required air spaces with insulation.

If area above is a room or

If area above is not a room, install

insulated area, install firestop

firestop below framed hole.

above framed hole.

 

Figure 20 - Installing Firestop

116234-01B

www.desatech.com

Page 13
Image 13
Desa (V)TC36NE, (V)TC36PE Installation for Vertical Termination, Flat Ceiling Installation, If area above is a room or

(V)TC36NE, (V)TC36PE specifications

Desa (V)TC36NE and (V)TC36PE are advanced heating solutions designed to provide both efficiency and comfort in residential and commercial settings. These two models stand out for their innovative engineering, modern design, and user-friendly features, making them ideal choices for individuals seeking reliable temperature control.

The central feature of both models is their high-efficiency combustion systems, which optimize fuel usage to reduce environmental impact while saving on heating costs. The (V)TC36NE and (V)TC36PE are equipped with state-of-the-art burners that ensure complete combustion, resulting in clean emissions and enhanced performance. With an exceptional energy rating, these units contribute to a greener environment by minimizing the carbon footprint.

Another notable characteristic is the versatile installation options these units offer. The (V)TC36NE, designed for natural gas use, can be seamlessly integrated into existing heating systems, while the (V)TC36PE operates with propane, catering to a broader range of installation scenarios. This flexibility enables homeowners and businesses to select the model that best fits their fuel supply and heating needs.

Both models come with advanced controls that grant users precise temperature regulation. With smart technology integration, users can operate these heating units remotely via smartphone applications, allowing for personalized heating schedules and real-time monitoring. This feature not only enhances user convenience but also promotes energy efficiency by preventing energy waste.

The design of the (V)TC36NE and (V)TC36PE models is another highlight, showcasing a sleek and contemporary aesthetic that complements various interior decors. The units are constructed with durable materials, ensuring longevity and reliability even under demanding conditions. Furthermore, their quiet operation enhances the overall comfort of the environment, making these units suitable for bedrooms, offices, and other noise-sensitive areas.

In summary, the Desa (V)TC36NE and (V)TC36PE models merge innovative technology with practical design and efficiency. With their advanced combustion systems, versatile installations, smart controls, and stylish appearance, they offer an ideal heating solution for modern living spaces. Homeowners and businesses looking to enhance their heating performance while maintaining environmental consciousness can find a compatible option in these exceptional models.