VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

9

VENTING INSTALLATION INSTRUCTIONS

Continued

Manual background WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exterior wall with four screws. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete or other types of sidings. Before attach- ing the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal between it and the outside wall.

Combustible Exterior Wall: For vinyl siding, stucco or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of standoff. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material.

7.Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12).

8.Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4" (see Figure 13, page 10).

9.Combustible Exterior Wall Only: Slide wall firestop against interior wall surface and attach with screws provided (see Figure 12). See Figure 13, page 10 for horizontal termination details.

Vent Cap

Wood Screw

Figure 10 - Installing Horizontal Vent Cap (Noncombustible Exterior)

Cut Siding Away to Fit Standoff

Standoff

Wood Screw

Vent Cap

Screws

Apply Mastic to All Four Sides

Figure 11 - Installing Siding Standoff (Combustible Exterior)

Interior Wall

Manual background Surface

Wall

Manual background Firestop

Vent Cap

Horizontal

(Horizontal

Vent Pipe

Termination)

 

Screw

Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe