VENTING INSTALLATION INSTRUCTIONS Installation Planning

VENTING INSTALLATION INSTRUCTIONS

Continued

INSTALLATION PLANNING

There are two basic types of direct-vent installation:

Horizontal Termination

Vertical Termination

Horizontal Termination Installation

IMPORTANT: Horizontal square terminations require only in- ner portion of wall firestop. Horizontal installations using round termination require exterior portion of wall firestop (see Figure 14, page 10).

1.Set the fireplace in its desired location and determine the route your horizontal venting will take. Do not secure the fireplace until all venting has been installed. Some installations require sliding the fireplace in and out of position to make final vent- ing connections. Figures 14 through 18 on pages 10 through 12 show different configurations for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired venting route. If they are, you may want to adjust the location of the fireplace.

2.Direct vent pipe sections and components are designed with special twist-lock connections.

Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approxi- mately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

3.Use a 45° elbow to connect venting system to fireplace flue collar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc.

4.Assemble the desired combination of pipe and elbows to the fireplace flue collar. If there are long portions of venting run, pre-assembled pipe sections may be installed as subassemblies for convenience.

5.Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10 3/4" x 10 3/4" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9).

Male

Female Slots

Locking

Lugs

Figure 8 - Vent Pipe Connections

Vent Opening

 

Combustible Wall

10 3/4" Inside Framing

10 3/4"

(273 mm)

(273 mm)

 

10 3/4"

 

(273 mm)

 

(Framing

Vent Opening

Detail)

 

Noncombustible Wall

 

8 1/2"

 

(216 mm)

 

 

Center

 

of Hole

Figure 9 - Vent Opening Requirements

www.desatech.com

116234-01B

Page 8
Image 8
Desa (V)TC36PE Installation Planning, Horizontal Termination Installation, Male Female Slots Locking Lugs, Center

(V)TC36NE, (V)TC36PE specifications

Desa (V)TC36NE and (V)TC36PE are advanced heating solutions designed to provide both efficiency and comfort in residential and commercial settings. These two models stand out for their innovative engineering, modern design, and user-friendly features, making them ideal choices for individuals seeking reliable temperature control.

The central feature of both models is their high-efficiency combustion systems, which optimize fuel usage to reduce environmental impact while saving on heating costs. The (V)TC36NE and (V)TC36PE are equipped with state-of-the-art burners that ensure complete combustion, resulting in clean emissions and enhanced performance. With an exceptional energy rating, these units contribute to a greener environment by minimizing the carbon footprint.

Another notable characteristic is the versatile installation options these units offer. The (V)TC36NE, designed for natural gas use, can be seamlessly integrated into existing heating systems, while the (V)TC36PE operates with propane, catering to a broader range of installation scenarios. This flexibility enables homeowners and businesses to select the model that best fits their fuel supply and heating needs.

Both models come with advanced controls that grant users precise temperature regulation. With smart technology integration, users can operate these heating units remotely via smartphone applications, allowing for personalized heating schedules and real-time monitoring. This feature not only enhances user convenience but also promotes energy efficiency by preventing energy waste.

The design of the (V)TC36NE and (V)TC36PE models is another highlight, showcasing a sleek and contemporary aesthetic that complements various interior decors. The units are constructed with durable materials, ensuring longevity and reliability even under demanding conditions. Furthermore, their quiet operation enhances the overall comfort of the environment, making these units suitable for bedrooms, offices, and other noise-sensitive areas.

In summary, the Desa (V)TC36NE and (V)TC36PE models merge innovative technology with practical design and efficiency. With their advanced combustion systems, versatile installations, smart controls, and stylish appearance, they offer an ideal heating solution for modern living spaces. Homeowners and businesses looking to enhance their heating performance while maintaining environmental consciousness can find a compatible option in these exceptional models.