10

INSTALLATION

Relocating Wall Switch Assembly (Cont.)

INSTALLATION

Continued

For Mantel Installation

If fireplace is to be installed into a mantel, (see Conventional Fireplace Installation, page 15) the wall switch assembly may be mounted on either side of the mantel, facing to the side. Do not locate wall switch assembly anywhere on the front face of the mantel.

CAUTION: Be careful of gas lines and wiring when moving floor.

1.Determine the new location for the wall switch assembly. The wires attached to switch are six feet long.

2.Remove 2 screws securing plastic wall switch assembly to bracket in fireplace lower cavity. Save screws.

3.Remove wire tie holding coiled wire attached to wall switch assembly (see Figure 8).

4.Remove wall switch assembly from bracket.

5.Carefully pass wall switch assembly and cord through large elongated hole in rear of either left or right floor support bracket, depending on desired location of switch. Pass wall switch as- sembly and cord through 1.5" diameter hole in side of fire- place outer casing (see Figure 9).

6.Pull wall switch assembly and cord from fireplace making sure wall switch assembly will reach desired mounting location without straining cord assembly.

If you are mounting wall switch assembly to a wall, continue reading. If you are mounting your wall switch assembly to the side of the mantel, see page 11.

Mounting Wall Switch Assembly to Wall for Recessed Fireplace

7.Create three openings on wall according to Template 1, page 33. This is best done by making a pattern to work with on your wall. Carefully cut page 33/34 from manual and tape paper template vertically onto wall at preferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leaving a mark on the wall. Do the same at centers of the four circles near the corners of the rectangle.

8.Remove paper template from wall.

9.Drill 3/8" holes at each mark.

10.Using a straight edge and pencil, connect the outer edges of the 4 holes for the rectangle (see Figure 10). This will give you cutting lines for the rectangle you will cut in the wall.

11.Using a keyhole saw, hack saw blade, drill, file, or other suit- able tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template.

12.From inside the recessed opening for the fireplace, carefully pass wall switch assembly through the rectangular opening to the outside of the wall.

13.Using wall anchors supplied in hardware package, fold wall anchor as shown in Figure 11.

14.Insert wall anchor, wings first, into hole. Tap anchor flush to wall.

15.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. See Figure 12. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick), do not pop open wings.

CAUTION: Do not apply excessive pull on cord.

Burner

Wire Tie

Firebox

Outlet

 

Bottom

Tube

 

 

 

Gas Control Valve

Wall Switch

Assembly

 

Figure 8 - Relocating Wall Switch Assembly

Make Marks

at Centers

of Holes

Template from This Manual

 

 

 

 

 

 

 

Cutting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8" Diameter

 

 

 

 

2 Holes

 

Lines

3/4"

43/4"

33/4"

3/8"

3/16"

Tape

Hole in Outer

Hole in

Casing

Floor

 

Support

 

Bracket

Wall Switch Assembly

Figure 9 - Routing Wall Switch Assembly Through Fireplace for Relocation

Figure 10 - Using Template for Wall Switch Assembly Installation

Figure 11 - Folding Anchor Figure 12 - Popping Open Anchor Wings for Thin Walls

For..com

110112-01A

Page 10
Image 10
Desa VTGF33NRA installation manual Relocating Wall Switch Assembly