OPERATING FIREPLACE

Normal Lighting Instructions

To Turn Off Gas To Appliance Manual Lighting Instructions for Electrical Power Outage

19

OPERATING FIREPLACE

Continued

4.To lower flame, push HI/LO button on wall switch once. Note: This fireplace does not have a pilot-only mode.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

5.To lower flame, point remote control toward lower front of fireplace and push HI/LO button once.

Note: This fireplace does not have a pilot-only mode.

TO TURN OFF GAS

TO APPLIANCE

HI/LO

Button

LED

Figure 37 - Control Locations

ON/OFF Button

Wall Switch

Assembly

Manual Ignition Bypass Switch (Up is for Remote Control)

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.

Shutting Off Heater - Wireless Remote Control

Point remote control toward lower front of fireplace and push both buttons at the same time.

MANUAL LIGHTING INSTRUCTIONS

Thermocouple

 

 

Manual

Automatic

Ignitor

Electrode

Ignitor

Electrode

Pilot

 

Burner

Figure 38 - Pilot (Propane/LP Gas Shown)

 

B. Using Hand-Held Wireless Remote Control

1. Set manual ignition bypass switch on control panel to OFF

position (automatic ignition position).

2. Wait five (5) minutes to clear out any gas. Smell for gas

around heater and near floor. If you smell gas, STOP! Fol-

low “B” in the safety information on warnings plate. If you

don’t smell gas, go to the next step.

3. Point remote control toward the lower front of fireplace

and push both buttons at the same time. Hold for 6 sec-

onds. The gas valve will open and electronic ignition will

begin sparking to light the pilot. Note: You will be able to

hear a clicking sound during this process. LED on wall

switch will light.

Note: You may be running this heater for the first time

after connecting to gas supply or at the start of your heat-

ing season. If so, the ON button may need to be pressed

again. This will allow air to bleed from gas system. If sev-

eral attempts to light pilot fail, contact a qualified service

person or gas supplier for repairs. Until repairs are made,

FOR ELECTRICAL POWER OUTAGE

WARNING: You must operate this heater with the fireplace screen in place. Make sure fireplace screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light automatically.

1.Follow steps 1 through 3 under Normal Lighting Instructions, pages 18 and 19.

2.Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 39.

3.The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs.

HI/LO

ON/OFF

LED

LED Button

Manual Ignition

Button

 

 

 

Bypass Switch

 

 

(Down is ON)

light and operate manually (see Manual Lighting Instruc-

tions for Electrical Power Outage).

4. When pilot flame is lit, the thermocouple is heated by the

flame. When thermocouple becomes hot (5 to 15 seconds),

main burner will automatically light on high flame.

Wall

Switch Piezo

Ignitor

Figure 39 - Control Locations

Gas

Valve

Magnetic Manual

Override Handle

For morevisit www..com

110112-01A

Page 19
Image 19
Desa VTGF33NRA installation manual To Turn OFF GAS To Appliance, Manual Lighting Instructions, For Electrical Power Outage