SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

1.

This appliance is only for use with the type of gas indicated on

 

the rating plate. This appliance is not convertible for use with

 

other gases.

2.

Do not place propane/LP supply tank(s) inside any structure. Lo-

 

cate propane/LP supply tank(s) outdoors (propane/LP units only).

3.

If you smell gas

 

shut off gas supply

 

do not try to light any appliance

 

do not touch any electrical switch; do not use any phone in

 

 

your building

 

• immediately call your gas supplier from a neighbor’s phone.

 

 

Follow the gas supplier’s instructions

 

• if you cannot reach your gas supplier, call the fire department

4.

This fireplace shall not be installed in a bedroom or bathroom.

5.

Do not use this fireplace as a wood-burning fireplace. Use only

 

the logs provided with the fireplace.

6.

Do not add extra logs or ornaments such as pine cones, ver-

 

miculite, or rock wool. Using these added items can cause soot-

 

ing. Do not add lava rock around base. Rock and debris could

 

fall into the control area of fireplace.

7.

To prevent the creation of soot, follow the instructions in Clean-

 

ing and Maintenance, pages 21 and 22.

8.

Before using furniture polish, wax, carpet cleaner, or similar

 

products, turn heater off. If heated, the vapors from these prod-

 

ucts may create a white powder residue within burner box or

 

on adjacent walls or furniture.

9.

This fireplace needs fresh air ventilation to run properly. This

 

fireplace has an Oxygen Depletion Sensing (ODS) safety

 

shutoff system. The ODS shuts down the fireplace if not enough

 

fresh air is available. See Air for Combustion and Ventilation,

 

pages 5 through 7. If fireplace keeps shutting off, see Trouble-

 

shooting, pages 23 through 25.

10.

Do not run fireplace

 

where flammable liquids or vapors are used or stored

 

under dusty conditions

11.

Do not use this fireplace to cook food or burn paper or other

 

objects.

12.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service technician to in-

 

spect the fireplace and to replace any part of the control sys-

 

tem and any gas control which has been under water.

16.To prevent performance problems with propane/LP units, do not use propane/LP fuel tanks of less than 100 lb. capacity.

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Log Set

Piezo Ignitor

Fan Switch

Base

Assembly

Figure 1 - Log Set and Base

Top Outer

Casing

Blower

Top LouverAssembly

Assembly

13.

Do not operate fireplace if any log is broken. Do not operate

 

fireplace if a log is chipped (dime-sized or larger).

14.

Turn fireplace off and let cool before servicing. Only a quali-

 

fied service person should service and repair fireplace.

15.

Operating fireplace above elevations of 4,500 feet could cause

 

pilot outage.

Screen

Assembly

Figure 2 - Fireplace

Bottom Louver Assembly

For morevisit www..com

110112-01A

Page 3
Image 3
Desa VTGF33NRA installation manual Product Identification, Other gases