Operation

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, above.

2.Turn gas shutoff valve to OFF.

3.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information, above. If you don't smell gas, go on to the next step.

4.Light a match and lay it on top of pan material about 2" from end of supply side of pan

5.Slowly turn gas shutoff valve ON until burner ignites. If burner doesn’t ignite within 10 seconds with match burning, turn shutoff valve OFF and repeat steps 1 through 4 again.

Gas shutoff

valve operation

Flame Adjustment

Adjust the flame ON/OFF by turning gas shut-

off valve counterclockwise to open or

clockwise to close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise to OFF position.

CURING

Logs

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as various paints and compounds used in manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

Operating

instructions FOR GA9050A-1

Note: Operation instructions for GA9050A-1 Remote Ready Valve/Pilot Kit will be included with the kit.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! Refer to the National Fuel Gas Codes, ANSI Z233.1/NFPA 54, Air for Combustion and Ventilation. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

to the PILOT position and press in. Keep control knob pressed in for five

(5)seconds.