Desa VVSA18M, VVSA24M, VVDA24M, VVDA18M Operating Appliance, For Your Safety Read Before Lighting

Models: VVDA30M VVDA24M VVDA18M VVSA18M VVSA24M

1 28
Download 28 pages 39.74 Kb
Page 9
Image 9

OPERATING APPLIANCE

For Your Safety Read Before Lighting

Curing Logs

Lighting Instructions

To Turn Off Gas To Appliance

9

OPERATING APPLIANCE

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

CURING LOGS

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information, column one.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! See Safety Information, page 2. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position and press in. Keep control knob pressed in for five

(5) seconds.

Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release igni- tor button. This will light pilot. Visually locate the pilot on the control valve cover by the edge of the burner pan to look for flame. If needed, keep pressing ignitor button un- til pilot lights.

Note: If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service tech- nician or gas supplier.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise to the ON position. Burner should light. If burner does not light, call a qualified service person.

Control Knob

Pilot

During the 2-3 hour appliance break-in period, you may detect

Ignitor

an odor from the appliance as the various paints and com-

 

pounds used in the manufacturing of this log set cure. This is a

 

normal and temporary situation that is not cause for alarm.

 

However, you may want to provide extra ventilation to the room

 

during this time.

 

 

ON

OFF

 

 

FROM "PILOT" POSITION

 

On

SLIGHT PUSH TO

Off

 

PULL PUSH

 

 

TURN OFF

 

ON OFF

FROM "PILOT" POSITION SLIGHT PUSH TO TURN OFF PULL PUSH

SLIGHT PUSH TO TURN OFF PULL PUSH

POSITION"PILOT"FROM OFFON

To ensure proper curing of the logs:

Figure 15 - Ignitor and Control Knob

• Ignite a 2" flame and maintain it for 1 hour.

Thermocouple

• Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

Pilot

Burner

Figure 16 - Thermocouple and Pilot

For more information, visit www.desatech.com

901268

Page 9
Image 9
Desa VVSA18M, VVSA24M, VVDA24M Operating Appliance, For Your Safety Read Before Lighting, Curing Logs Lighting Instructions

VVDA30M, VVDA24M, VVDA18M, VVSA18M, VVSA24M specifications

Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M are advanced heating solutions that combine efficiency, versatility, and user-friendly features. These models are popular among consumers looking for reliable heating systems for their homes or businesses.

The Desa VVSA series, which includes the VVSA24M and VVSA18M models, is designed for high-performance utilization, making them ideal for medium to large spaces. These units utilize advanced radiant heating technology, which effectively warms up a room by emitting infrared heat, making them energy-efficient and environmentally friendly. The VVSA24M model offers a higher heat output, catering to larger areas, while the VVSA18M is suitable for smaller spaces, providing ample warmth without the added bulk.

On the other hand, the Desa VVDA series comprises the VVDA18M, VVDA24M, and VVDA30M models. This series is notable for its dual-fuel capability, allowing users to choose between propane and natural gas for fuel, enhancing flexibility depending on availability and cost. The VVDA variances cater to different heating needs, with the VVDA30M boasting the highest output, making it perfect for extensive commercial settings or sizable residential spaces. The VVDA18M and VVDA24M serve as excellent alternatives for smaller establishments, maintaining efficient heating performance while reducing energy consumption.

One of the standout features across all these models is the integrated electronic ignition system, which ensures a reliable start and enhances safety by eliminating the need for a continuous pilot light. Additionally, these units are equipped with advanced thermostat controls, allowing users to set their desired temperature accurately and maintain a consistent level of comfort throughout the space.

These Desa models also feature durable construction with high-quality materials, ensuring longevity and resistance to wear and tear. Their sleek designs mean they can fit seamlessly into various interior decors, making them not just functional but also aesthetically pleasing.

In summary, Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M encompass a range of heating solutions that cater to diverse needs and preferences. With their innovative technologies, user-friendly features, and robustness, these units exemplify what modern heating systems should offer. They are not just about warmth; they bring comfort, efficiency, and flexibility to any space.