TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After pilot lights, keep control knob

 

 

 

 

pressed in 30 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local natural or propane/LP

 

 

which allows thermocouple to cool, caus-

 

gas company

 

 

ing pilot flame to go out. This problem could

 

 

 

 

be caused by one or both of the following:

 

B) Clean pilot (see Cleaning and Mainte-

 

 

A) Low gas pressure

 

nance, page 10) or replace pilot assembly

 

 

B) Dirty or partially clogged pilot

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten

 

 

trol valve

 

1/4 turn more

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

7.

Control valve damaged

7.

Replace control valve

 

 

 

 

 

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

4.

Thermocouple leads disconnected or im-

4.

Reconnect leads

 

 

properly connected

 

 

 

 

 

 

 

Delayed ignition burner

1.

Pilot flame needs adjusting

1.

Adjust pilot flame for approximately

 

 

 

 

2" blue flame

 

2.

Wrong pilot orifice

2.

Replace pilot orifice set