INSTALLING

INSTALLING GLASS PANEL

HEATER

For Radiant Models Only

1. Locate the glass panel package inside the back of the heater.

Continued

 

 

 

WARNING ICONG 001 CAUTION

 

 

Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, call DESA International’s Technical Ser- vice Department at 1-800-323-5190 for replacement glass panels.

WARNING ICONG 001 CAUTION

Do not operate heater without glass panels installed. Operating heater without glass panels will damage front of heater due to excess temperatures.

WARNING ICONG 001 CAUTION

Glass panels may have sharp edges. Handle with care.

2.Remove lower front access panel of heater by removing two screws at upper corners of panel. The lower front access panel covers the lower front access area (see Figure 9, page 14).

3.Remove two screws on glass guard. Remove glass guard (see Figure 11).

4.Carefully insert one glass panel up through lower front access area (see Figure 11).

5.Carefully slip glass panel behind hearth assembly (see Figure 11).

Glass

Guard

Screw

Hearth

Assembly

Glass

Panel

Lower Front

Access Area

Figure 11 - Inserting Glass Panels