Desa Tech CGR65PA, CGR65BPA, CGR35PA, CGR50BPA Blower, Wiring, Diagram, Changing Burner Orifice

Models: CGR50BPA CGR65BPA CGR65PA CGR35PA CGR50PA

1 44
Download 44 pages 19.34 Kb
Page 34
Image 34

 

SERVICE

 

PROCEDURES

 

 

Continued

 

Changing Burner Orifice

Burner

1.

Shut off gas supply to

 

 

heater.

 

2.

Remove lower front

 

 

access panel on heater.

Orifice

3.

Disconnect burner tube

 

 

from orifice holder (see

Burner

 

Figure 25).

 

Tube

4.

Remove orifice holder

 

 

from burner (see Figure

 

 

25).

 

5.

Use socket or open-end

 

 

wrench to remove the old

Orifice

 

orifice from the orifice

 

Holder

 

holder.

 

6.

Clean and replace orifice,

Figure 25 - Orifice Location (35,000 BTU/Hr Burner Shown)

 

or replace with new

 

 

 

orifice.

 

7.

Turn on gas to heater and

 

 

check for gas leaks. Apply

 

 

a mixture of liquid soap

 

 

and water to all joints.

 

 

Bubbles forming show a

 

 

leak. Correct all leaks at

 

 

once.

 

8.Replace lower front access panel.

Figure 26 - Orifice

BLOWER

 

 

Fan Switch

 

 

 

 

 

 

 

WIRING

 

 

(Off/On/Auto)

 

 

 

 

 

Auto

 

 

 

 

 

 

 

 

DIAGRAM

 

 

Off

 

 

 

 

 

 

 

 

(For Models With

 

 

On

 

Fan

 

 

 

 

Red

Blower Assembly)

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

Black Blue

 

(N.O.)

 

 

 

 

 

 

Black

 

 

 

 

 

 

Blower

 

110/115 V.A.C.

 

Motor

 

 

 

Black

 

Red

 

 

 

 

 

 

 

 

 

White

 

White

 

 

 

Green

 

 

 

 

 

 

 

 

 

34

100793

Page 34
Image 34
Desa Tech CGR65PA, CGR65BPA, CGR35PA, CGR50BPA, CGR50PA installation manual Blower, Wiring, Diagram, Changing Burner Orifice