LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local

 

 

codes, use the latest edition of the following:

 

 

 

• National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 *

 

 

 

• National Electrical Code ANSI/NFPA 70 *

 

*Available from: American National Standards Institute, Inc., 1430 Broadway,

 

New York, NY 10018; National Fire Protection Association, Inc., Batterymarch

 

Park, Quincy, MA 02269.

 

 

 

UNPACKING

1. Remove heater from carton.

 

 

 

 

 

 

 

 

2. Remove all protective packaging applied to heater for shipment.

 

3. Check heater for any shipping damage. If heater is damaged, promptly inform

 

 

dealer where you bought heater.

 

 

PRODUCT

Piezo Ignition System

 

 

 

This heater has a piezo ignitor. This system requires no matches, batteries, or other

FEATURES

sources to light heater.

 

 

 

 

Thermostatic Heat Control

 

 

 

 

This heater has a thermostat sensing bulb and a control valve. This results in the

 

greatest heating comfort. This can also result in lower gas bills.

INSTALLING

 

 

 

 

 

 

 

 

 

WARNING

 

HEATER

 

 

WARNING ICONG 001

 

 

 

A qualified service person must install heater and

 

 

 

 

venting system. Have them inspect heater before use

 

 

 

 

and at least annually. Follow all local codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTICE

 

 

 

 

This heater must be electrically grounded if equipped with

 

 

 

 

blower. Follow all local codes. In the absence of local

 

 

 

 

codes, follow the National Electric Code, ANSI/NFPA 70.

 

 

 

 

 

 

 

 

CHECK GAS TYPE

 

 

 

 

Use only propane gas. If your gas supply is not propane, do not install heater. Call

 

dealer where you bought heater for proper type heater.

 

INSTALLATION ITEMS

 

 

 

 

Before installing heater, make sure you have all items below.

 

external regulator (supplied by

test gauge connection * (see

 

 

installer, see page 11)

 

Figure 7, page 12)

 

piping (check local codes)

sediment trap

 

sealant (resistant to propane gas)

tee joint

 

• manual shutoff valve *

• pipe wrench

 

ground joint union

venting materials

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 37.

6

100793

Page 6
Image 6
Desa Tech CGR35PA, CGR65BPA, CGR50BPA, CGR50PA Unpacking, Features, Installing Heater, Check GAS Type, Installation Items

CGR50BPA, CGR65BPA, CGR65PA, CGR35PA, CGR50PA specifications

Desa Tech's CGR series, including the CGR50PA, CGR35PA, CGR65PA, CGR65BPA, and CGR50BPA, represents a cutting-edge line of gas logs designed for efficiency, reliability, and user-friendly operation. Each model combines modern engineering with top-tier technologies to deliver warmth and aesthetic appeal to any living space.

The CGR50PA is known for its compact yet powerful heating capabilities, offering a maximum input of 50,000 BTUs. This model is ideal for smaller rooms, providing consistent warmth without taking up excessive space. Its advanced burner technology ensures a realistic flame appearance, enhancing the ambiance of any setting.

The CGR35PA stands out with its lower BTU output of 35,000, making it perfect for cozy spaces or homes looking for a supplemental heating source. This model emphasizes energy efficiency, utilizing a state-of-the-art control system that optimizes fuel consumption while maintaining performance and comfort.

In contrast, the CGR65PA is designed for larger areas, boasting an impressive output of 65,000 BTUs. This model features a dual burner system, which not only increases heat distribution but also adds to the visual appeal with varying flame heights. Its robust construction guarantees durability, and an easy-to-use remote control provides added convenience.

The CGR65BPA variant further increases efficiency with its built-in blower system, which circulates warm air throughout the room, ensuring even heating. This model is particularly useful in expansive living areas where traditional heating methods may fall short. Its innovative safety features, including an oxygen depletion sensor, provide peace of mind for users.

Lastly, the CGR50BPA combines the advantages of its siblings, offering a balanced heating solution for medium-sized rooms. With a blower and adjustable thermostat, this model allows users to tailor their heating experience. Each unit in the CGR series is compatible with natural gas or propane, maximizing versatility based on individual preferences or regional availability.

Overall, the Desa Tech CGR series epitomizes modern gas log technology, focusing on performance, efficiency, and safety, making them an excellent choice for anyone seeking reliable and attractive heating solutions.