Desa Tech CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB Connecting To Gas Supply

Models: CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB CRL2718PA, CRL2718NA, CRL3124PA, CRL3124NA, CCL3018PA, CCL3018NA, CCL3924PA, CCL3924NA, CCL3018PTA, CCL3018NTA, CCL3924PTA, CCL3924NTA, CCL3930PTB, CCL3930NTB

1 40
Download 40 pages 1.02 Kb
Page 13
Image 13
8.Remove heater base from fireplace.

INSTALLATION

Continued

7.Mark screw locations through holes in mount- ing brackets (see Figure 12 and 13). If install- ing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12 or 13).

Masonry

Screw

Mounting

Bracket

Figure 12 - Attaching Base Assembly to Fireplace Floor - Dual Burner Model

Masonry

Screw

Mounting

Bracket

Figure 13 - Attaching Base Assembly to Fireplace Floor - Single Burner Model

CONNECTING TO GAS SUPPLY

CONNECTING TO GAS SUPPLY WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

•external regulator (supplied by installer) WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

•piping (check local codes) CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an externalregulator(notsupplied). Install the external regulator be- tweentheheaterandpropane/LP supply.

•sealant (resistant to propane/LP gas) WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 38.

113097-01D

www.desatech.com

13

Page 13
Image 13
Desa Tech CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB Connecting To Gas Supply, Remove heater base from fireplace