Turn control knob clockwise  to the OFF position.

OPERATING HEATER

Continued

5.Turn control knob counterclockwise Turn control knob clockwise  to the PILOT position. to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise THERMOSTAT to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Figure 32 - Control Knob and Ignitor to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Button Location to the PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, pages 21 and 22.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, column 1.

OFF

Figure 33 - PilotManual backgroundManual backgroundManual backgroundManual backgroundManual background Pilot Manual background

Ignitor Button

Control Knob

 

Figure 32 - Control Knob and Ignitor

 

Button Location

Ignitor

Pilot Burner

Electrode

Thermocouple

Figure 33 - Pilot