Desa Tech installation manual Optional Positioning Of Thermostat Sensing Bulb

Models: CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB CRL2718PA, CRL2718NA, CRL3124PA, CRL3124NA, CCL3018PA, CCL3018NA, CCL3924PA, CCL3924NA, CCL3018PTA, CCL3018NTA, CCL3924PTA, CCL3924NTA, CCL3930PTB, CCL3930NTB

1 40
Download 40 pages 1.02 Kb
Page 28
Image 28
OPTIONAL POSITIONING

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

FOR MASONRY AND FACTORY- BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem- perature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb elsewhere, an adhesive- backed mounting clip is available.

Tools needed: 1/4" hex driver or socket

1.Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 38).

2.With 1/4" hex driver or socket, loosen the ther- mostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 40).

Note: Do not remove the screw. Make sure you tighten the screw after removing the thermostat sensing bulb.

IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.

3.The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sensing bulb, but do not mount sens- ing bulb until step 4. If you have a masonry fire- place, see Figure 41 for location. If you have a factory-built metal fireplace, see Figure 42 for location. If your fireplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 43).

Figure 39 - Adhesive-backed Mounting Clip

Capillary

Thermostat

Screw

 

Retaining

 

Clamp

 

 

Thermostat

 

Sensing

 

Bulb

Figure 40 - Removing Thermostat

Sensing Bulb

Thermostat

 

Sensing Bulb

 

Adhesive-backed

 

Mounting Clip

 

Figure 41- Locating Thermostat Sensing

Bulb on Masonry Fireplace

 

Thermostat

 

Sensing Bulb

 

Adhesive-

 

backed

 

Mounting Clip

Gas Valve

Assembly

Mounting

Thermostat

Bracket

Sensing

 

Bulb

Figure 38 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Figure 42 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace

Thermostat

Sensing Bulb

Adhesive-backed

Mounting Clip

Glass Doors

Figure 43 - Installing Thermostat Sensing Bulb Behind Glass Doors

28

www.desatech.com

113097-01D

Page 28
Image 28
Desa Tech Optional Positioning Of Thermostat Sensing Bulb, For Masonry And Factory- Built Metal Fireplace