Desa Tech RFP30T installation manual Inspecting Burner, Cleaning Maintenance, Cabinet

Models: RFP30T

1 24
Download 24 pages 7.29 Kb
Page 15
Image 15

OWNER'S MANUAL

INSPECTING

BURNER

Check pilot flame pattern and burner flame

pattern often.

PILOT FLAME PATTERN

Figure 26 shows a correct pilot flame pat- tern. Figure 27 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the

thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 27

turn heater off (see To Turn Off Gas to Appliance, page 14)

seeTroubleshooting, pagesl6throughl8

Pilot Burner

Thermocouple

Figure 26 - Correct Pilot Flame Pattern

PilotBurner

Thermocouple

Figure 27- Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 28 shows a correct burner flame pattern. Figure 29 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.

Note: When using the heater the first time, the flame will be yellow for approximately one hour until the log cures.

Ak WARNING: If yellow tipping

occurs, your heater could pro- duce Increased levels of carbon

monoxide. If burner flame pat- tern shows yenowtipping, follow instructions at bottom of this

page.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 29

turn heater off (see To Turn OffGas to Appliance, page 14)

seeTroubleshooting, pagesl6throughl8

Top of Flame About

One Inch Above Logs

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 28 - Correct Burner Flame Pattern

at High Position

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure29-1ncorrectBurnerFlame Pattern at High Position

CLEANING AND

MAINTENANCE

_lb WARNING: Turn off heater

and let cool before cleaning.

_k CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater Inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

ODS/PILOT AND BURNER

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi- net to remove dust.

Yellow