15,000 TO 30,000 BTU/HR

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS l

1.STOP! Read the safety information, page 13, column 3.

2.Make sure manual shutoff valve is fully open.

3.Turn control knob clockwise F-_to the OFF position.

IgnitorButtonControlKnob

Figure 24 - Control Knob In The OFF Position

4. Wait five

(5) minutes

to clear out any

gas. Then smell for gas, including

near the

floor. If

you smell gas,

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knoK

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The main burner should light. Set con-

trol knob to any heat level between

HI and LO.

_]k CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

IgnitorElectrode

Thermocouple

CONTROL

l THERMOSTAT l

OPERATION

The thermostatic control used on this heater differs from standard thermostats.

Standard thermostats simply turn on and off the burner. The thermostat used on

this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or de-

creases the burner flame height. At times the room may exceed the set tempera- ture. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tem- perature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc_). Frequent use of your heater will let you determine your own comfort levels.

STOP! Follow "B" in the safety in-

formation page 13, column 3. If you

don't smell gas, go to the next step.

5. Turn control knob counterclockwise

cnontrotO the PILOT position. Press

!knob for five (5) seconds

(see Figure 24).

Note: You may be running this heater for the first time after hook-

ing up to gas supply. If so, the con-

trol knob may need to be pressed in for 30 seconds. This will allow air to

bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot _,hts.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 16 through 18. Also contact a qualified service person or gas supplier for repairs.

 

 

 

 

 

l

MANUALPROCEDURELIGHTING l

Figure 25 - Pilot

 

 

 

1.

Remove front panel (see Figure 2,

TO TURN OFF GAS

1

2.

page 4).

 

Follow steps I through 5 under Light-

TO APPLIANCE

BB

ing Instructions.

Shutting

Off Heater

 

 

3. With control knob pressed in, strike

 

 

 

match. Hold match to pilot until pi-

1. Turn

control

knob

clockwise

 

 

lot lights.

 

to the OFF position.

 

 

 

 

4. Keep control knob pressed in for 30

 

 

 

 

 

2. Turn off all electric power to the ap-

seconds after lighting pilot. After 30

pliance if service is to be performed.

seconds,

release control knob.

 

 

 

 

 

 

Shutting

Off Burner Only (pilot

5.

Replace

front panel.

stays lit)

 

 

 

 

 

 

 

Turn control knob dockwlse

F-_

 

to

 

 

the PILOT

position.

 

 

 

 

 

 